50W 60W 72W wazi frame byte umeme Kiwanda
Vigezo/Vigezo vya Umeme:
Mfano Na | TA65-5V10A | TA65-12V5A | TA65-24V3A | TA65-36V2A | |
Pato | DC voltage | 5V | 12V | 24V | 36V |
Iliyokadiriwa sasa | 10A | 5A | 3A | 2A | |
Masafa ya sasa | 0-10A | 0-5A | 0-3A | 0-2A | |
nguvu iliyokadiriwa | 50W | 60W | 72W | 72W | |
Ripple na Kelele (Upeo wa juu) | 50mVp-p | 100mVp-p | 120mVp-p | 150mVp-p | |
Usahihi wa voltage | ±5% | ±3% | ±3% | ±3% | |
Kiwango cha marekebisho ya mstari | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Udhibiti wa Mzigo | ±1% | ±1% | ±1% | ±1% | |
Ufanisi (TYP) | 88% | 85% | 88% | 89% | |
Aina ya marekebisho ya voltage | haiwezi kurekebishwa | ||||
Kuanza, wakati wa kupanda | 1500ms, 30ms/220VAC 2500ms, 30ms/110VAC (mzigo kamili) | ||||
Ingizo | safu ya voltage | VAC100-240V(85-264V) VDC127~370V (Tafadhali rejelea "Derating Curve"). | |||
Masafa ya Marudio | 50/60Hz | ||||
AC ya sasa (TYP) | 0.6A/220VAC,1.2A/100V | 0.65A/220VAC,1.25A/100V | |||
Inrush sasa (TYP) | KUANZA BARIDI 45A | ||||
kuvuja kwa sasa | <2mA/240VAC | ||||
Ya sasa Ulinzi | mzunguko mfupi | Hali ya ulinzi: hali ya hiccup, kurejesha moja kwa moja baada ya hali isiyo ya kawaida kuondolewa | |||
juu ya sasa | 110% ~ 200% ya pato lililokadiriwa sasa | ||||
juu ya nguvu | 110% ~ 200% ya nguvu ya pato iliyokadiriwa | ||||
Kimazingira | Joto la uendeshaji | ﹣20~﹢60℃ (Tafadhali rejelea "Derating Curve") | |||
Unyevu wa kazi | 20 ~ 90%RH, hakuna ufupishaji | ||||
Joto la kuhifadhi na unyevu | ﹣40~﹢85℃,10~95%RH | ||||
Inastahimili mtetemo | 10~500Hz, 2G dakika 10/mzunguko, mhimili wa X, Y, Z kila dakika 60 | ||||
Usalama na Utangamano wa Kiumeme | kanuni za usalama | Rejelea CE, CCC, muundo wa kawaida wa IT, kwa kweli unahitaji kampuni yako kupita mtihani kulingana na mahitaji ya udhibitisho. | |||
Upinzani wa shinikizo | I/PO/P:3KVAC | ||||
Upinzani wa insulation | I/PO/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70%RH | ||||
Uzalishaji wa Upatanifu wa Umeme | Rejelea CE, CCC, muundo wa kawaida wa IT, kwa kweli unahitaji kampuni yako kupita mtihani kulingana na mahitaji ya udhibitisho. | ||||
Kinga ya Utangamano wa Umeme | Rejelea CE, CCC, muundo wa kawaida wa IT, kwa kweli unahitaji kampuni yako kupita mtihani kulingana na mahitaji ya udhibitisho. | ||||
Mitambo | Ukubwa (L*W*H) | 130*50*30mm(L*W*H) | |||
uzito | Takriban 0.5Kg/PCS |
Maoni:
Isipokuwa ikiwa imebainishwa vinginevyo, vipimo vyote hupimwa chini ya uingizaji wa 220VAC, mzigo uliokadiriwa, na halijoto ya mazingira ya 25°C.
Ugavi wa umeme unapaswa kuzingatiwa kama sehemu ya vipengele vya mfumo, na uthibitisho unaofaa wa utangamano wa umeme unapaswa kufanywa kwa kushirikiana na vifaa vya terminal.
Kupunguza Mviringo
Mkondo wa Tabia tuli
*Mchoro wa Vipimo vya Mitambo: kitengo MM
*Mchoro wa Mzunguko wa Nguvu:
Andika ujumbe wako hapa na ututumie