200W 240W 300W Watengenezaji wa Ugavi wa Nguvu wa Mfululizo wa Fremu Wazi
Vigezo/Vigezo vya Umeme:
Mfano Na | MA200-24V8A | MA200-24V10A | MA200-36V8A | MA200-48V5A | |
Pato | DC voltage | 24V | 24V | 36V | 48V |
Iliyokadiriwa sasa | 8A | 10A | 8A | 5A | |
Masafa ya sasa | 0-12A | 0-15A | 0-10A | 0-7A | |
nguvu iliyokadiriwa | 200W | 240W | 300W | 240W | |
Ripple na Kelele (Upeo wa juu) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
Usahihi wa voltage | ±3% | ±3% | ±3% | ±3% | |
Kiwango cha marekebisho ya mstari | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Udhibiti wa Mzigo | ±1% | ±1% | ±1% | ±1% | |
Ufanisi (TYP) | 87% | 87% | 88% | 89% | |
Mbinu ya baridi | Bure baridi | Kupoza kwa feni (10CFM) | Kupoza kwa feni (10CFM) | Kupoza kwa feni (10CFM) | |
Kuanza, wakati wa kupanda | 1500ms, 30ms/220VAC 2500ms, 30ms/110VAC (mzigo kamili) | ||||
Ingizo | safu ya voltage | VAC100-240V (Tafadhali rejelea "Derating Curve") | |||
Masafa ya Marudio | 50Hz/60Hz | ||||
AC ya sasa (TYP) | 220V1.8A/110V3A | 220V2.2A/110V3A | 220V2.7A/110V3A | 220V2.2A/110V3A | |
Inrush sasa (TYP) | KUANZA BARIDI 35A | ||||
kuvuja kwa sasa | <2mA/240VAC | ||||
Ya sasa | mzunguko mfupi | Hali ya ulinzi: hali ya hiccup, kurejesha moja kwa moja baada ya hali isiyo ya kawaida kuondolewa | |||
juu ya sasa | 110% ~ 200% ya pato lililokadiriwa sasa | ||||
juu ya nguvu | 110% ~ 200% ya nguvu ya pato iliyokadiriwa | ||||
Kimazingira | Joto la uendeshaji | ﹣20~﹢60℃ (Tafadhali rejelea "Derating Curve") | |||
Unyevu wa kazi | 20 ~ 90%RH, hakuna ufupishaji | ||||
Joto la kuhifadhi na unyevu | ﹣40~﹢85℃,10~95%RH | ||||
Inastahimili mtetemo | 10~500Hz, 2G dakika 10/mzunguko, mhimili wa X, Y, Z kila dakika 60 | ||||
usalama | Upinzani wa shinikizo | I/PO/P:1.5KVAC | |||
sInsulation upinzani | I/PO/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70%RH | ||||
Mitambo | Ukubwa (L*W*H) | 125*66*35mm(L*W*H) (35MM ni urefu wa vijenzi vya ubao) | |||
uzito | Takriban 0.8Kg/PCS |
Maoni:
Isipokuwa ikiwa imebainishwa vinginevyo, vipimo vyote hupimwa chini ya uingizaji wa 220VAC, mzigo uliokadiriwa, na halijoto ya mazingira ya 25°C.
Ugavi wa umeme unapaswa kuzingatiwa kama sehemu ya vipengele vya mfumo, na uthibitisho unaofaa wa utangamano wa umeme unapaswa kufanywa kwa kushirikiana na vifaa vya terminal.